Measuring Range:0.6-508mm
Application:UM-5 series ultrasonic thickness gauges are used for measuring Metal and Nonmetal materials i.e. Plastic, Steel, PVC, Glass Plates and Pipes. They can be widely used in the fields such as manufacturing and metal processing, etc. It can also make detection on various kinds of pipes and pressure vessels of the manufacturing facilities about their thickness lossing after corrosion.">

加勒比亚洲激淫在线视频-亚洲国产成人av第一二三区-亚洲欧美日韩激情一区-中文日韩不卡视频在线观看

UM-5 Series Ultrasonic Thickness Gauge

Model:UM-5 / UM-5D / UM-5DL
Measuring Range:0.6-508mm
Application:UM-5 series ultrasonic thickness gauges are used for measuring Metal and Nonmetal materials i.e. Plastic, Steel, PVC, Glass Plates and Pipes. They can be widely used in the fields such as manufacturing and metal processing, etc. It can also make detection on various kinds of pipes and pressure vessels of the manufacturing facilities about their thickness lossing after corrosion.

Video Demo

Instruction Book Download

Brochure Download





圖片關鍵詞

圖片關鍵詞

圖片關鍵詞

圖片關鍵詞

圖片關鍵詞

The UM-5 series ultrasonic thickness gauges developed and produced by Yushi Instruments adopt the Ultrasonic pulse reflection principle. Acoustic waves are emitted into the material from one side of the workpiece and the thickness can be measured in real time without cutting the workpiece. It is an ultra-small measuring instrument. It can measure quickly, without damage, and accurately. In addition, the instrument provides A and B scanning functions. The echo display can help users control the measurement better, make the thickness measurement range wider and the measurement value more accurate.

This instrument can be widely used in manufacturing, metal processing, aerospace, railway transportation, chemical industry, commodity inspection and other inspection fields. In addition to measure various kinds of plates and processed parts accurately, it can also monitor the thinning after corrosion of the pipelines and pressure vessels in production equipment. It is an essential equipment on non-destructive testing industry.


The main functions of UM-5DL are as follows:

Real-time color A-scan


The user can see the color ultrasonic signal wave pattern on the screen, which is essential for occasions where it is necessary to verify whether the thickness reading is correct. In many cases, erroneous thickness readings or even no readings can cause confusion. According to the A-scan waveform, the problem can be easily solved.  And according to the waveform, the three parameters of gain (GAIN), blanking (BLANKING) and gate (GATE) need to be adjusted appropriately, then correct thickness reading can be obtained.

  Adjustable gate


Only when the echo is higher than the gate, the instrument considers the echo is received and will have a measured value, which shows the importance of adjustable gate, especially in applications that deal with low echo signals (such as the measurement of ultra-thin plates and ultra-thick plates).

Red Arrow


A-scan mode has a red arrow indicating the measuring point, and the thickness reading is the abscissa of this point. It can help user to judge whether the thickness reading is correct or not. When measuring correctly, the red arrow should point to the front end of the first bottom echo.

Gain adjustment


Adjust the magnification of the echo signal, allowing manual increase or decrease in units of ldB. This function is very effective for measuring sound attenuating materials (such as metal castings).


Blanking function


Invalidating the waveform in the range of the red blanking bar can eliminate clutter wave that affects the measurement, such as noise caused by the rough surface of the material or internal unevenness.

Range


Adjust the range of the waveform displayed on the screen, the waveform is visually compressed or expanded. If the display range has not been set correctly, the echo waveform may be out of the display area and cannot be seen, but the measured value can still be displayed correctly.

Delay


Adjust the starting position of the waveform displayed on the screen, the waveform can be moved horizontally visually. If the translation has not been set correctly, the echo waveform might be out of the display area and cannot be seen, but the measured value can still be displayed correctly. The range and delay function can magnify any part of the waveform and display it on the screen.

Real-time color B-scan


UM-5 series ultrasonic thickness gauges are equipped with real-time B-scan function, which displays the profile view of the workpiece along the moving track of the probe, which is used to observe the bottom surface profile of the workpiece. Capture the minimum value on a B-scan image automatically, and the position of the minimum value is indicated by the red triangle sign. You can also view the thickness of any point on the B-scan image by moving the pointer.

Larger memory, more convenient storage function


It can store 100,000 thickness values and 1000 A and B scan waveforms. The waveforms and thickness values can be stored in the same file; by using grid-style storage files and 15 thickness values can be displayed on one screen and displayed in the grid at the same time. It is convenient for users to browse the stored thickness data. USB 2.0 Full Speed (Full Speed) interface, powerful DataView data statistics and management software.

Other useful functions


Difference/reduction rate: The difference mode displays the difference change between the measured thickness and the preset thickness. The reduction rate is to calculate and display the percentage of thickness reduction after the material becomes thinner. A typical application is to measure metal materials that have become thinner due to bending.

◆ Maximum/minimum value capture: The current thickness, minimum and maximum thickness values are displayed on the screen at the same time.

◆ Alarm mode: dynamically change the color of the thickness reading when alarming.

◆ Adjustable update rate of 4Hz, 8Hz, 16Hz: 4Hz can be selected for common applications, and a higher update rate can be selected when fast scanning is required, such as high temperature measurement.


Display

2.4 inches color OLED, 320 X 240 pixels, contrast 10,000:1

Operating Principle

Pulse echo with dual element transducers

Measuring Range

0.50mm to 508mm(0.025" to 20.00"), depending on material, probe and surface condition0.

Limits of Tube (Steel)

Φ20mm×3.0mm(Standard probe)
Φ15mm×2.0mm(PT-06 probe)
The measuring error is up to ±0.1mm

Resolution

Selectable 0.01mm,0.1mm( 0.001",0.01")

Gain

Adjustable

Probe Calibration

One-Point Calibration, Two-Point Calibration

Measuring Error

±0.05mm (Low limit to 25mm)
±0.2%H(25mm to 100mm)
±0.5%H(100mm to Up Limit)

Update Rate

Selectable 4Hz, 8Hz, 16Hz

Material Velocity Range

500 to 9999m/s (0.0197 to 0.3937in/us)

Stability of the Values

Based on full digital technology, with zero cross measurement technology, the measured value will not be affected by echo intensity, material attenuation coefficient, gain and the height of gate, keep high measurement stability and reliability.

Repeatability

±0.05mm

Display Mode

Normal, Minimum / Maximum capture, DIFF/RR%

V-Path Correction

Automatic

Languages

Selectable Chinese, English, Germany, etc.

Alarm Settings

Minimum and Maximum alarms.
Dynamic waveform color change on alarm

Power

2 AA size batteries

Operating Time

Approximately 24 hours

Instrument Shut-off

Selectable ALWAYS ON or AUTO OFF after 5, 10, 20 minutes of inactivity

Capacity

100,000 readings, 1000 waveforms, 400 files

Operating Temperature

-10°C to +50°C (+10°F to +120°F)

Size

153mm × 76mm ×37mm(H × W × D)

Warranty

1 year

Weight

200g(including batteries

Standard Configuration

Ultrasonic Thickness Gauge,Standard Probe,Instrument Case,Couplant Bottle,Operating Manual, Certification, Packing List.

Optional Accessories

Various Probes, Probe Cables, Step Calibration Blocks, Communication Software and Rubber Bumpers.

Function Comparisions

Feature

UM-5

UM-5D

UM-5DL

Color Display

Live A-Scan

Time-based B-Scan

Control of Gain and Gate

Blanking

Thru-paint&coatings

×

Data Logger

×

×

DataView Software

×

×

Optional Ultrasonic Probes

Model

PT08

PT06

PT04

ZT12

GT12

Type

Common

Small Tube

Fingertip

Cast iron

H-Temperature

Frequency

5MHZ

7.5MHZ

10MHZ

2MHZ

5MHZ

Diameter

11mm

8mm

6mm

17mm

15mm

Range

0.8-100mm

0.8-30mm

0.7-12mm

4.0-508mm

4.8-80mm

Temperature

-10 ~70℃

-10 ~70℃

-10 ~70℃

-10 ~70℃

-20 ~450℃


產(chǎn)品列表
Add:No.9, Shenbei Road, Shenbei New District, Shenyang, China 110136 Email:sales03@yushindt.com QQ:3468612256 Phone:+8618640030218
+8615998314917">
亚洲欧美成人影院一区| 久久成人精品一区电影| 70国产精品一区二区| 成人午夜电影久久影院| 亚洲中文乱码一区二区三区| 国产美女久久久亚洲综合| 亚洲欧美狂白浆一区二区| 午夜福利网站在线观看| 原创国产在线导航av| 亚洲中文字幕99精品| 色吧欧美黑人一区二区| 国产精品麻豆成人av| 狠狠精品干练久久久久久| av天堂视频在线观看| 国产av一区二区精品| 精品国产车一区二区三区| 猛操熟女一区二区三区| 日韩不卡视频在线免费观看| 国产亚洲精品久久久久9999| 人妻少妇久久中文字幕一区| 久久亚洲精品视频网站上| 欧美精品91一区二区三区 | 久草最新福利视频在线观看| 国产av精品高清一区二区三区| 欧美日韩亚洲国产天堂| 国产日韩欧美在线播放| 亚洲乱码中文字幕高清| 秋霞鲁丝片一区二区三区| 91麻豆久久一级中文字幕| 国产精品自拍视频麻豆| 中文字幕一区二区综合网| 亚洲女同中文字幕一区二区| 欧亚一区二区三区av| 亚洲熟女另类自拍日韩丝袜| 日本最新加勒比在线观看| 欧美乱码精品一区二区| 日本黑人亚洲一区二区| 欧美三级a做爰全过裸体| 国产精品白丝美女在线观看| 福利一区二区在线播放| 四虎高清成人在线观看|